top of page
blue-1634110_1280.png

Energy Product (BdHd) is a figure of merit representing the magnetic energy a permanent magnet can supply to an external circuit at a specific operating point along its second-quadrant demagnetization curve. Its peak value—known as the Maximum Energy Product, or (BH)max—measures the highest magnetic energy efficiency achievable by a given magnet grade and serves as the industry benchmark for comparing permanent magnet strength.

Industrial Applications

In real-world magnetic engineering, energy product determines how compactly a permanent magnet can generate a required magnetic field inside a working air gap. Because magnets operate within larger mechanical assemblies rather than open space, an engineer shapes pole pieces, return paths, and magnet geometry (such as the length-to-diameter ratio) to set the circuit's permeance coefficient (Pc), or load line. Aligning that load line so it intersects the normal demagnetization curve right at the (BH)max coordinate allows the assembly to achieve its target air-gap flux using the smallest possible magnet volume and weight—an essential advantage in brushless DC (BLDC) motors, voice coil actuators, hermetic magnetic couplings, and space-constrained aerospace or medical assemblies.

Technical Specifications
Core Formulas

  • Energy Product at Operating Point:

    Energy Product = Bd × Hd

    Where:

    • Bd = Operating flux density (magnetic induction) on the demagnetization curve, measured in Gauss (G) or Tesla (T)

    • Hd = Demagnetizing field strength at that specific operating point, measured in Oersteds (Oe) or kiloamperes per meter (kA/m)

  • Maximum Energy Product:

    (BH)max = Peak value of (Bd × Hd) along the second-quadrant demagnetization curve

  • Ideal Magnet Volume Formula (SI Units):

    Vm = (Bg² × Vg) / (μ₀ × Bd × Hd)

    Where:

    • Vm = Magnet volume (m³)

    • Bg = Required air-gap flux density (T)

    • Vg = Air-gap volume (m³)

    • μ₀ = Permeability of free space (4π × 10⁻⁷ H/m)

    • Engineering Note: This equation uses SI units (in CGS units, μ₀ drops out) and represents the ideal case, which assumes infinite permeability and zero flux loss in the connecting iron core. In practical circuit design, engineers multiply the numerator by a leakage factor and a reluctance factor (commonly estimated between 1.0 and 1.2 when empirical measurements are unavailable) to account for stray flux and core losses. Because Vm is inversely proportional to (Bd × Hd), operating near (BH)max minimizes required magnet volume.


Units and Conversion Factors

  • CGS Unit: Megagauss-Oersteds (MGOe or MGO)

  • SI Unit: Kilojoules per cubic meter (kJ/m³)

  • Conversion Rate:

    • 1 MGOe = 7.9577 kJ/m³

    • 100 kJ/m³ = 12.566 MGOe


Typical Commercial Material Ranges

  • Sintered Neodymium Iron Boron (NdFeB): Typically 30 to 52 MGOe (240 to 415 kJ/m³). Grade N50 is generally the highest broadly available commercial tier, N52 is achievable in select geometries, and specialized ultra-high grades can reach 55 to 56 MGOe. (By contrast, bonded NdFeB is significantly lower, typically 3.5 to 12 MGOe or 28 to 96 kJ/m³.)

  • Samarium Cobalt (SmCo): Typically 16 to 32 MGOe (130 to 255 kJ/m³).

  • Alnico Alloys: Typically 1.1 to 5.5 MGOe (9 to 44 kJ/m³), with workhorse grades like Alnico 5 delivering roughly 4.5 to 5.0 MGOe and specialized directional grades reaching slightly higher.

  • Hard Ceramic / Ferrite: Typically 1.1 to 4.5 MGOe (9 to 36 kJ/m³), ranging from low-energy isotropic or flexible grades near 1.1 MGOe up to high-grade anisotropic Ceramic 8 around 3.5 to 4.5 MGOe.


Common Engineering & Manufacturing Challenges

  • Thermal Demagnetization and the Hcj Trade-Off: Elevated operating temperatures pose two distinct risks to energy product. First, because (BH)max scales roughly with the square of remanence (Br²) on a linear demagnetization curve, energy product declines at roughly twice the percentage rate of Br as temperature rises (for sintered NdFeB, Br drops around −0.12%/°C). Second, and far more dangerous, intrinsic coercivity (Hcj) falls five to six times faster than Br (roughly −0.55% to −0.75%/°C). Because ultra-high-(BH)max grades like N52 sacrifice Hcj to maximize Br, their resistance to demagnetization collapses rapidly in warm environments, pushing the operating point past the demagnetization curve's "knee" and causing permanent flux loss.

  • Permeance Line (Load Line) Mismatch: Designing a magnet that is too thin relative to its pole area (a low length-to-diameter, or L/D, ratio) creates strong self-demagnetizing fields. This forces the operating slope well below the (BH)max point, underutilizing the material's available energy and requiring oversized magnets to reach target field levels.

  • Batch-to-Batch Property Spread: International standards such as ASTM and IEC publish minimum magnetic property specifications rather than tight upper-and-lower tolerances, and commercial datasheets typically list nominal (BH)max ranges spanning a few percent (for example, N35 is commonly rated at 33 to 36 MGOe). Engineers should apply finite element analysis (FEA) sensitivity margins to verify performance across normal production lot variation.

Related Case Studies and Products

Optimize Your Magnetic Circuit for Maximum Efficiency

Don't guess your operating point on paper. Whether you are miniaturizing a voice coil actuator or engineering a custom permanent magnet assembly for high-temperature service, QT Magnetic Solutions delivers the FEA modeling, alloy selection, and precision manufacturing needed to optimize your energy product.

ENERGY PRODUCT

QT Magnetic Solutions     561 Monterey Rd.       Morgan Hill, CA 95037       (408) 261-3589

© CONTENT COPYRIGHT 2026 QT MAGNETIC SOLUTIONS. ALL RIGHTS RESERVED.

bottom of page